Metabolomics LC-MS (Xevo G2-XS)

Image
Image of a G2-XS with Acquity LC and UPC2 systems

MS Staff Member:
John Walsby-Tickle

Location:
Basement MS (00.097)

Booking:
Sample submission, contact John Walsby-Tickle for more information

Training required:
Yes

Training prerequisites:
Previous experience using LC-MS or SFC-MS systems

Instrument description:

The Waters Xevo G2-XS is a bench-top QTOF mass spectrometer, designed for the analysis of a wide range of compounds in complex and challenging samples. The instrument incorporates StepWaveTM ion-transfer optics which increase the efficiency of ion transfer and remove neutral species from the ion beam, increasing sensitivity. The instrument is equiped with an ESI LockSprayTM source to allow accurante mass analysis by direct infusion or by LC. The XS collision cell allows fast and sensitive MS/MS experiments to be performed alongisde conventional experiments. This system used for metabolomics projects. The MS can be used either with a conventional Acquity LC system or a UPC2 for supercritical fluid chromatography.

Typical applications:

High resolution LC-MS, metabolomics, lipidomics

Agilent GC-MSD User Information

Bruker MALDI Sample Preparation

Combining Trypsin/Chymotrypsin Enzymatic Digestion

GC-MS (Agilent 7200)

IC-MS (Q Exactive)

In-Gel Trypsin Enzymatic Digestion

In-solution Chymotrypsin Enzymatic Digestion

In-solution protein digestion

MALDI Oligonucleotide Sample Preparation

MALDI User Information

MassLynx

Metabolomics

Metabolomics LC-MS (Xevo G2-XS)

Native MS Sample Preparation

Preparation of blood plasma for metabolomics

Preparation of cell samples for metabolomics

Preparation of plant samples for metabolomics

Preparation of tissue samples for metabolomics

Rapid Digestion - Promega Trypsin/Lys-C Kit

RP-HPLC Purification of Oligonucleotides

Sample Preparation Protocol for Alternative Ionisation Service

Sample Preparation Protocol for BioAccord 1 Intact Protein Analysis

Sample Preparation Protocol for BioAccords

Sample Preparation Protocol for ESI Accurate Mass Service

BioTools logo

BioTools

Bruker logo

flexAnalysis

Image of a GC-MS

GC-MS (Agilent 7200)

Image of a Q Exactive IC-MS

IC-MS (Q Exactive)

Matrix Science logo

Mascot

Agilent logo

MassHunter

Logo for MassLynx

MassLynx

Logo for MaxQuant

MaxQuant

Logo for Mestrenova

Mestrenova

Image of an LC-MS system

Metabolomics

Image of a G2-XS with Acquity LC and UPC2 systems

Metabolomics LC-MS (Xevo G2-XS)

Logo for PEAKS software

PEAKS Q

Placeholder

Preparation of blood plasma for metabolomics

Placeholder

Preparation of cell samples for metabolomics

Placeholder

Preparation of plant samples for metabolomics

Placeholder

Preparation of tissue samples for metabolomics

Logo for Proteome Discoverer

Proteome Discoverer

Image of a G2-XS with Acquity LC and UPC2 systems

SFC-MS (UPC2-Xevo G2-XS)

SpectralWorks icon

SpectralWorks RemoteAnalyzer

Xcalibur logo

Xcalibur